RRC ID 43769
著者 Tanabe R, Cha BY, Ha BG, Yonezawa T, Nagai K, Woo JT, Yagasaki K.
タイトル Detection of adiponectin and monocyte chemoattractant protein-1 using a calixcrown derivatives-coated protein chip.
ジャーナル J Immunoassay Immunochem
Abstract We used a ProteoChip coated with a calixcrown derivative protein linker to measure adiponectin and monocyte chemoattractant protein-1 (MCP-1) levels and compared the results with commercial enzyme-linked immunosorbent assay (ELISA) kits. Adiponectin and MCP-1 levels in normal human serum and RAW264 cell supernatants, respectively, were measured. The ProteoChip quantification results correlated with those from the ELISA kits; however, the ProteoChip required less sample volume, exhibited higher sensitivity, and had a wider detection range. The ProteoChip was capable of detecting and quantifying small amounts of protein, possibly replacing ELISA kits in evaluating the levels of adiponectin and MCP-1.
巻・号 33(2)
ページ 166-79
公開日 2012-1-1
DOI 10.1080/15321819.2011.615360
PMID 22471607
MeSH Adiponectin / analysis* Adiponectin / immunology Animals Antibodies, Monoclonal / immunology Calixarenes / chemistry* Calixarenes / immunology Cell Line Chemokine CCL2 / analysis* Chemokine CCL2 / immunology Crown Ethers / chemistry* Crown Ethers / immunology Enzyme-Linked Immunosorbent Assay Humans Mice Protein Array Analysis / instrumentation Protein Array Analysis / methods* Recombinant Proteins / analysis Recombinant Proteins / immunology Sensitivity and Specificity
引用数 0
WOS 分野 BIOCHEMICAL RESEARCH METHODS IMMUNOLOGY MEDICAL LABORATORY TECHNOLOGY
リソース情報
ヒト・動物細胞 RAW 264(RCB0535)